DESCRIPTION:
Laminar air flow ceilings ensures efficient protection against contamination which can occur during invasive acts and caused by airborne dead or living particles.
The ceilings are available in square or rectangular shapes in order to suit any room layout and answer specific requirements to create a clean zone around the patient, medical staff and medical devices.
Aerobiologically, the things that generate most airborne contamination in an operating theatre are the staff. The most common unit of contamination (colony forming unit – “cfu”) is a microcolony on an airborne skin scale. That microcolony will contain between 1 and 1,000 bacteria. (Microbial numbers are a critical factor in initiation of infection). A significant purpose of operating theatre ventilation is to prevent airborne bacteria from settling-out in (the wound).
Our laminar flow ceilings are mainly used with our Clinicair Air Handling Unit, but can be also adapted to any type of products from a different brand. This system is dedicated to operating theatres in order to meet ISO 5 standard (complying with EN ISO 14644-1) as well as to pharmaceutical industry. It helps fight cross contamination and hospital borne infections.
Ceiling Laminar Air Flow provides ultra clean sterile HEPA filtered class 100 air in an isolated area where the highly sensitive process activities are carried-out. Ceiling Laminar Air Flow available in complete stainless steel construction or galvanized iron construction with powder coated finish. Equipped with minipleat HEPA with dynamically balanced ultra-low noise blowers for optimum airflow.
TECHNICAL SPECIFICATIONS OR ORDERING DETAILS:-
MODEL | ASI-CLAF/42 | ASI-CLAF/44 | ASI-CLAF/64 | ASI-CLAF/86 |
Internal dimension (L x B) | 1300x700mm | 1300x1300mm | 2000x1300mm | 2600x1950mm |
Outer dimensions (L X B) | 1200x600mm | 1200x1200mm | 1800x1200mm | 2400x1200mm |
Air Velocities | 0.45 ± 0.05 mps | |||
Air Flow | Vertical | |||
Noise Level | Less than 65 dB | |||
Vibration Level | Minimum | |||
Light intensity | > 300 lux | |||
Power Supply | 230V AC supply 50HZ | |||
Two Stage filtration | • EU6 – Prefilter (95% down to 5 micron) • EU14 – HEPA Filter (99.997% down to 0.3 micron) at supply position |
|||
Motor-blower | Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level during operation. | |||
Side panels | Glass side panels | |||
Lights | Fluorescent Lights with Milky White Diffuser | |||
Pressure Gauge | Differential Pressure Gauge | |||
Timer | Clean Down Timer with Operation Hold indicator | |||
Additional Feature | · DOP Test Port